Continuous Sutures Outperform Staplers in Burn Surgery Skin Graft Scar
A randomized clinical trial comparing wound closure techniques in burn surgery has revealed that simple continuous nylon sutures produce significantly better scar edge outcomes than surgical staplers. The single-blind trial, conducted by researchers at Mazanda
Illustrative imageA randomized clinical trial comparing wound closure techniques in burn surgery has revealed that simple continuous nylon sutures produce significantly better scar edge outcomes than surgical staplers. The single-blind trial, conducted by researchers at Mazandaran University of Medical Sciences, evaluated aesthetic and healing markers using the validated Vancouver Scar Scale over a three-month postoperative period. Investigators tracked hospitalized burn patients requiring autologous skin grafting under general anesthesia to evaluate how continuous four-zero nylon sutures and mechanical staplers influence scar quality and healing along the boundary between grafted and normal skin. While mechanical staplers enabled substantially faster graft fixation during surgery, objective follow-up evaluations demonstrated that continuous sutures yielded consistently superior scar ratings at both one and three months post-discharge.
Burns occur when skin contacts open fire, electricity, extreme temperatures, hot objects, or chemicals, with damage depth classified across four distinct clinical degrees. Worldwide, burns account for five to twelve percent of all documented trauma cases, ranking as the fifth most frequent cause of non-fatal injuries among children while inflicting higher mortality rates among women. In Iran, annual burn injuries affect between one hundred thousand and one hundred and fifty thousand people, causing approximately three thousand deaths and requiring hospital admission in six percent of cases. Burn injuries impose severe societal burdens, as more than seventy percent of survivors develop irregular scars, with contractures, painful joint stiffness, and persistent skin dryness enduring years after injury.
Pathological healing frequently produces raised hypertrophic scars that remain confined to original wound edges, or extensive keloids that invade neighboring tissue. While surgical literature confirmed that precise edge approximation markedly reduces scarring compared to overlapping margins, empirical data evaluating closure mechanics specifically at the graft-to-normal-skin boundary remained scarce. The current clinical trial directly addresses this dilemma by comparing continuous four-zero nylon sutures against mechanical staplers to determine the optimal closure approach for burn graft sites.
To establish an empirical comparison, the research team designed a single-blind, randomized controlled trial registered under code IRCT20250409065268N1 following ethics approval from Mazandaran University of Medical Sciences. The trial enrolled sixty consecutive adult patients aged nineteen to seventy-five who required elective or emergent skin grafting under general anesthesia for deep second-degree, third-degree, or fourth-degree burns. Study eligibility required confirmed literacy, voluntary informed consent, and absence of substance abuse, while individuals with immunodeficiency disorders, advanced renal disease, glycated hemoglobin concentrations exceeding 6.5 percent, or premature study withdrawal were excluded. Using computer-generated block randomization with blocks of four, participants were allocated equally into two cohorts of thirty individuals: group A underwent graft fixation using disposable Chinese CYS mechanical staplers, whereas group B received wound closure using non-absorbable four-zero nylon continuous sutures. Randomization codes were sealed within opaque envelopes opened by surgeons immediately prior to graft fixation, ensuring patients remained blinded to their allocated closure technique.
Patients admitted to the burn unit underwent surgical blister debridement two days following admission, followed by alternating wound irrigation using normal saline and diluted betadine alongside sharp excision of non-viable tissue. Debridement sessions were performed every second day across three scheduled treatment intervals before applying silver sulfadiazine ointment or advanced dressings. Grafts were stored in sterile normal saline and processed using a mesh graft device before placement over the wound bed. In the intervention arm, surgeons secured graft margins using CYS staplers, while control grafts were anchored using continuous four-zero nylon sutures. Sterile saline dressings were refreshed every forty-eight to seventy-two hours, with fasteners removed six to eight days postoperatively prior to discharge.
Baseline demographic characteristics, including sex distribution, age, height, weight, and body mass index, were well matched between groups with no statistically significant differences. Mean participant age was 46.27 years in the stapler group and 43.00 years in the suture group, while average body mass index measured 25.81 and 26.41, respectively. Graft margins were primarily located on the lower limbs, upper limbs, trunk, and head or face. Assessment of graft edge scar quality using the Vancouver Scar Scale revealed statistically significant differences favoring continuous sutures at every measurement interval. At one month post-discharge, the suture cohort achieved a mean scar score of 6.30 compared to 7.80 in the stapler cohort. By three months, scores improved across both cohorts, recording 5.34 for sutures versus 7.14 for staplers.
Advanced statistical modeling using Generalized Estimating Equations substantiated the primary observational findings, establishing that closure technique, elapsed healing duration, and anatomical graft location served as statistically significant independent predictors of scar scores. In multivariable analysis, continuous nylon sutures accounted for an overall mean reduction of 2.04 scar score units relative to mechanical stapling across the postoperative observation timeline. Scar maturation over time produced an additional beneficial effect, with overall scores declining by an average of 0.83 units between the first and third postoperative months. Anatomical positioning also played a vital prognostic role; graft margins situated across the trunk achieved scar ratings that were 1.45 units lower than those located on the head or facial regions. Conversely, demographic parameters such as patient age, biological sex, height, and body mass index demonstrated no meaningful correlation with scar scores, confirming that surgical technique and regional tissue dynamics exert the dominant influence on aesthetic scarring.
While continuous sutures provided superior cosmetic results, mechanical staplers demonstrated undeniable procedural speed during graft placement. Measuring the operative duration required to secure a ten-centimeter graft border showed that ninety percent of stapler applications were completed within fifteen seconds, with ten percent concluding in under five seconds and thirty-three point three percent under ten seconds. In contrast, eighty-six point seven percent of continuous suture closures required more than fifteen seconds, with forty-six point seven percent taking under five minutes and forty percent requiring up to ten minutes. Stapler removal was also faster, with sixty-six point seven percent extracted within ten seconds compared to sutures, where ninety percent required between ten and thirty seconds. However, stapler extraction necessitated local re-anesthesia in forty-three point three percent of patients, compared to only three point three percent among suture patients. Although pain scores on the Numerical Rating Scale did not differ significantly between groups, supplemental anesthesia during staple extraction presents clinical risks for patients with cardiovascular or respiratory fragility.
Analysis of secondary complications demonstrated comparable safety profiles between closure methods, though distinct mechanical complications affected the stapler group. Surgical site infection rates were identical between groups, with two patients in each cohort developing localized infections representing an incidence of six point seven percent. Graft edge dehiscence occurred in thirteen point three percent of stapler patients and sixteen point seven percent of suture patients, while severe itching exceeding five episodes daily affected twenty-six point seven percent and thirty percent of patients, respectively, without statistical significance. However, mechanical complications showed notable divergence; the stapler group experienced four cases of retained surgical instruments where metal staples became embedded within healing tissue, representing a thirteen point three percent retention rate, whereas no retained sutures occurred. Furthermore, the stapler group experienced three complete graft losses representing a ten percent failure rate during the first month, compared to zero graft losses in the suture cohort, highlighting differences in graft retention.
The trial findings present a fundamental clinical dilemma in burn reconstruction, balancing intraoperative efficiency against long-term scar morphology and patient safety. While mechanical staplers shorten surgical time and reduce anesthesia exposure—benefits of importance during extensive burn operations—their higher purchasing costs, risk of staple retention, and frequent need for removal re-anesthesia represent notable drawbacks. Conversely, continuous four-zero nylon sutures provide superior edge apposition, eliminate hardware retention, preserve graft integrity, and achieve significantly better aesthetic scar scores at lower material costs. The study authors emphasized important limitations, noting that the three-month follow-up window precluded observation of complete scar maturation or potential late convergence between techniques, while patient-reported outcome measures were not gathered.
Subject of Research: Surgical wound closure techniques and scar outcomes in burn skin grafting
Article Title: Comparison of graft edge scar scores and related indices using simple continuous sutures versus staplers in burn surgery sites
Article References: Hesamirostami, M., Rashidpour, A., Nasiri Formi, E., Hosseinnataj, A., Khodabakhsh, E., Jamali, A., & Amini, M. (2026). Comparison of graft edge scar scores and related indices using simple continuous sutures versus staplers in burn surgery sites. Burns Open, 16, Article 100496. https://doi.org/10.1016/j.burnso.2026.100496
Image Credits: AI Generated
DOI: 10.1016/j.burnso.2026.100496
Keywords: burn surgery, skin grafting, wound closure, simple continuous sutures, surgical staplers, Vancouver Scar Scale, hypertrophic scarring, graft edge dehiscence, autologous skin graft, surgical site infection, clinical trial, Mazandaran University of Medical Sciences, nylon sutures, reconstructive surgery, postoperative complications, scar quality
News Source: Ophelia Keating. (November 26, 2026). Continuous Sutures Outperform Staplers in Burn Surgery Skin Graft Scar Outcomes. Scienmag.